We produce universal as well as highly customized AC motors with rotation axes height from 56 to 100 mm that find a myriad of applications in various industries.
AC Motors applications: wood and metal working machines, hydraulic devices, air conditioning, medical and refrigeration industries and a myriad of other electric machines.
The output power is guaranteed if the electric motor is constructed in compliance with S1 operating conditions and conforms to DIN, VDE 0530 part 1 standards, 50 Hz supply system frequency, up to 40C environment temperature and not more than 1000 m
altitude.
In case of deviation, the output power could be changed according to the table below:
Temperature
oC
30
35
40
45
50
55
60
Output Power
%
106
103
100
96
92
87
82
Height
M
1000
1500
2000
2500
3000
3500
4000
Output Power
%
100
97
94
90
86
82
77
The driving shaft end torque N.m. can be calculated using the following formula:
M=9.55 x P x 1000/n, where:
P-nominal power in kW and n is revolutions per minute.
Single-row ball bearings two-sides closed with low noise level are used in the electric motors. The types of bearings used are shown in the next table
Size
Type
Front bearing
Rear bearing
56
MO.MOER
6200-2Z,C6
6200-2Z,C6
63
MO.MOER
6201-2Z,C6
6201-2Z,C6
80
MO.MOER
6204-2Z,C6
6204-2Z,C6
90
MO.MOER
6205-2Z,C6
6205-2Z,C6
100
MO
6206-2Z,C6
6206-2Z,C6
The motors are designed in compliance with the following operating standards
IEC/ISO
DIN VDE
NAME
IEC 34-1
DIN VDE 0530 Teil1
Rotating electrical machines. Rating and performance.
IEC 34-8
DIN VDE 0530 Teil 8
Rotating electrical machines. Part 8: Terminal markings and direction of rotation of rotating machines.
IEC 85
VDE 0530 Teil 1
Insulating materials
IEC 72
Joining and overall dimensions.
IEC 72
DIN 42 673 Teil 1
Joining dimensions and accordace of output ratings of type IM B3.
IEC 72
DIN 42 677 Teil 1
Joining dimensions and accordace of output ratings of type IM B5, IM B14.
IEC 34-5
EN 60 034 Teil 5 DIN VDE 0530 Teil 5 IEC 34-5
Rotating electrical machines. Part 5: Classification of degrees of protection by enclosures of rotating electrical machines (IP code).
IEC 34-6
DIN VDE 34-6
Rotating electrical machines. Part 6: Methods of cooling (IC code).
IEC 34-7
DIN IEC 34 Teil 7 IEC 34-7
Rotating electrical machines. Part 7: Classification of types of constructions and mounting arragements (IM code).
Rotating electrical machines. Starting characteristics of single-speed three-phase asynchronous electric motors with cage
rotor for supply voltages, lower or equal to 660 V.
IEC 38
DIN IEC 38
Stadart voltages recommended by IEC.
IEC 252
DIN VDE 0560 Teil 8
Condensers; motor condensers.
The electric motors execution and assembly type can be seen here
are designed for nominal supply voltage of 220/380 V, connection delta/Y and frequency of 50 Hz. At customer's request the motors can be designed with nominal supply voltage up to 400 V connection delta and up to 690 V connection Y and frequency of 60 Hz. Parameters are guaranteed with deviations of the nominal voltage no more than +/- 5%.
Prolonged operating conditions - S1 according to DIN 42950. Protection of electric and terminal devices from contact, foreign body and water penetration is, according to DIN 40050, IP 54, but can be designed with IP 55 degree of protection at customers request.
The insulation material of the primary winding is class "F" according to VDE 0530.
The above parameters are guaranteed at: maximum environment temperature up to 40C. maximum altitude up 1000 m. normal climatic conditions N II.
The motors can also be in tropical (TH II) or marine (M) version, while the shape can be B3, B5 and B14 according to IEC 72, DIN 42673 and DIN 42677.
are designed for nominal supply voltage of 220 V and frequency of 50 Hz. At customers request the motors can be designed with nominal supply voltage from 110 to 250 V and frequency of 60 Hz.
Parameters are guaranteed with deviations of the nominal voltage no more than +/- 5%.
Prolonged operating conditions - S1 according to DIN 42950. Protection of electric and terminal devices from contact, foreign body and water penetration is, according to DIN 40050, IP 54, but can be designed with IP 55 degree of protection at customers request.
The insulation material of the primary winding is class "F" according to VDE 0530.
The above parameters are guaranteed at: maximum environment temperature up to 40C. maximum altitude up 1000 m. normal climatic conditions N II.
The motors can also be in tropical (TH II) or marine (M) version, while the shape can be B3, B5 and B14 according to IEC 72, DIN 42673 and DIN 42677.
The motors are single-phase, induction, shaded pole motors with or without thermal protection. Nominal supply voltage is 110-250 V and supply system frequency of 50/60 Hz.
Operation mode of the motors is S1 according to DIN 42950, while protection rate is IP 44 (DIN 40050).